VMware vCenter Zero-Day CVE-2026-123890: Chinese Espionage Group Had Admin Access for Two Months Before the Patch
← back to insights
InsomniSec Team · November 24, 2026

VMware vCenter is the control panel for most corporate data centers; from one screen, an administrator can start, stop, copy, or open nearly every server the business runs. On November 19, Broadcom patched a flaw that let anyone who can reach vCenter on the network log in as its top administrator without a password. A Chinese state-linked espionage group had been using it since early September, more than two months before the fix existed, and in at least one confirmed intrusion it used that access to forge logins that bypass multi-factor authentication and to copy the Active Directory database, the master list of every user and password hash in the company's Windows network. Patching last summer's vCenter flaws did not help; the attackers hit a server that was already fully patched at the time. There is no workaround. Every organization running vCenter should treat this update as an emergency change this week, and, if vCenter was reachable from systems an attacker could have compromised, should check for signs it was already used.

The flaw is tracked as CVE-2026-123890 and rated CVSS 9.8 (Critical). It was fixed in VMware Security Advisory VMSA-2026-0009, which also addresses four lower-severity issues in SDDC Manager and VMware Tools for Windows. Mandiant reported the vulnerability to Broadcom, and Google Threat Intelligence Group (GTIG) and Mandiant attribute the attacks to ARMORY CASTLE, the suspected China-nexus group formerly tracked as UNC5221. This article covers how the attack worked, what VMSA-2026-0009 fixes, a patching pitfall that can block your next VMware Cloud Foundation upgrade, and what to do in what order.


At a glance

Advisory VMSA-2026-0009, published November 19, 2026
Headline flaw CVE-2026-123890, authentication bypass in the VMware Directory Service (vmdird), CVSS 9.8
What an attacker needs Network access to vCenter; no credentials, no user interaction
What an attacker gets An authenticated session as administrator@vsphere.local
Exploitation Zero-day use by ARMORY CASTLE since early September 2026, per GTIG and Mandiant
Workarounds None, per Broadcom
Fixed vCenter builds 9.1.1.0200, 9.0.2.0200, 8.0 U3m (VCF 5.x via 5.2.5 async patching)
vCenter 7.0 Affected; no public patch, extended support customers must contact Broadcom
Also fixed Three SDDC Manager flaws (CVSS 6.7 to 8.1) and one VMware Tools for Windows flaw (CVSS 6.7)
ESX hosts Not affected by this advisory; no VM escape
Broadcom priority Emergency change under ITIL

Why this one matters more than a typical critical CVE

vCenter vulnerabilities are always serious, because vCenter holds the keys to everything running on top of it. Three things make this one worse than usual.

It was a true zero-day, used by a capable espionage actor. GTIG and Mandiant report that ARMORY CASTLE exploited CVE-2026-123890 in early September 2026, well before Broadcom's fix. The exploit tool they recovered, BONESAW, carries a build timestamp of July 13, 2026. GTIG notes that this metadata can be altered, but if accurate, it means the group held the exploit for months. Mandiant CTO Charles Carmakal has said the company investigated multiple incidents involving this exploitation, so the published case study is unlikely to be the only victim.

Patching July's vCenter flaws did not protect anyone. In July, Broadcom fixed CVE-2026-59309, another 9.8-rated authentication bypass in the same Directory Service component, and CVE-2026-59310, a Syslog server path traversal that CISA added to its Known Exploited Vulnerabilities catalog in August after attacks linked to ransomware on ESXi hosts. BONESAW was run against a vCenter that had already been patched for CVE-2026-59309. Broadcom describes the new flaw as a new and distinct issue: CVE-2026-59309 was abused over LDAP, while CVE-2026-123890 goes through a separate RPC channel. Both end in the same place, an administrator session with no password.

The attackers went after identity, not just servers. Once inside vCenter, ARMORY CASTLE stole the key vCenter uses to sign login tokens. With that key, an attacker can mint valid logins for any user, bypassing MFA entirely, a technique known as Golden SAML. Patching closes the door the attackers came in through; it does nothing about a signing key that has already been stolen.


How the vulnerability works

CVE-2026-123890 lives in the VMware Directory Service (vmdird), the component behind vCenter's built-in single sign-on. According to GTIG, the flaw is in an RPC service that handles Secure Remote Password (SRP-6a) authentication over DCE/RPC on TCP port 2012, the control interface for vCenter SSO. Predictable, time-based UUIDv1 values used in that interface allow an unauthenticated attacker to recover the shared session key that would normally only be established after a correct password. With that key in hand, the attacker holds an authenticated session as administrator@vsphere.local, the most privileged account in vCenter.

From there, the vmdird RPC interface lets the attacker run commands and pull files, including the directory database itself (/storage/db/vmware-vmdir/data.mdb), which contains the SSO token-signing material.

A few details worth noting:

  • Enhanced Linked Mode does not matter. vCenter is affected whether or not it is enabled.
  • ESX hosts are not directly affected, and none of the five flaws allows code execution on an ESX host from inside a VM. In practice that offers little comfort; whoever controls vCenter controls the hosts it manages.
  • Mandiant reports that BONESAW works against vCenter 7.x and 8.x. vSphere 7 reached End of General Support on October 2, 2025, and there is no public patch for it.

Inside the ARMORY CASTLE intrusion

GTIG and Mandiant published a detailed account of one intrusion. It is worth reading in full, but the sequence below is what matters for defenders, because it shows that vCenter was the second zero-day in the chain, not the first.

  1. Initial access through BeyondTrust. The group first broke into a BeyondTrust Remote Support appliance using a separate zero-day, CVE-2026-102764 (CVSS 9.3), exploited since late August and described by GTIG in October.
  2. A pivot to blind spots. From there, the attackers moved to an internal Linux appliance with no EDR coverage and planted two JSP web shells, SLIMSAVAGE and CAGEMATCH, for command execution and file uploads. They escalated to root by injecting into a running process with gdb to make /bin/env SUID.
  3. Reconnaissance. They scanned internal subnets with nmap for VMware services, including ports 2012, 5480, 9080, 443, and 389.
  4. vCenter takeover. BONESAW exploited CVE-2026-123890, created a new SSO administrator account, copied the directory database, and extracted the token-signing key.
  5. Golden SAML. SAWSNAKE, a Go port of a public vCenter SAML login script, used the stolen key to forge administrator tokens and session cookies, bypassing MFA.
  6. Persistence. BEARBONES, a backdoored build of the Dropbear SSH server, listened on TCP ports 53 and 33992, logged plaintext credentials, and accepted a hardcoded password. The attackers created a local vCenter administrator (sps-<REDACTED>@vsphere.local), enabled SSH through the appliance management API, harvested the vCenter master encryption key and PostgreSQL credentials, and then switched SSH back off.
  7. Into the hypervisors. They logged into ESXi hosts as vpxuser and root, added an SSH key to root's authorized_keys, and used a Python tool to mount VMFS volumes and read virtual disks directly. From a Windows VM's disk, they extracted NTDS.dit (the Active Directory database) along with the SYSTEM and SECURITY registry hives.
  8. Exfiltration and long-term access. Archives were pulled back to the BeyondTrust appliance, from which GTIG says they were likely exfiltrated. A Go backdoor, LAZYBONES, which uses Slack for command and control and was previously seen in a 2025 Ivanti Connect Secure intrusion, was installed on another Linux appliance as a service named vmtoolscs.

GTIG noted that using two zero-days and three sets of custom malware in a single intrusion indicates significant resources, and that BONESAW was likely built for broader operations than this one victim. No victims, sectors, or countries have been named. ARMORY CASTLE has targeted edge and security appliances since at least 2023, and the group's earlier BRICKSTORM activity consistently focused on vCenter and ESXi as long-term hiding places.

The lesson for leadership is that the attack never touched a well-monitored system until it was already in control. The edge appliance, the Linux appliance, and the vCenter appliance are all the kind of systems where endpoint security tools are rarely installed.


Everything VMSA-2026-0009 fixes

CVE Product What it is CVSS Attacker needs Fixed in
CVE-2026-123890 vCenter Authentication bypass in VMware Directory Service 9.8 Critical Network access only 9.1.1.0200, 9.0.2.0200, 8.0 U3m; VCF 5.x via 5.2.5
CVE-2026-123891 SDDC Manager SQL injection allowing database read/write 8.1 Important Authenticated, low privileges 9.1.1.0200, 9.0.2.0100, 5.2.5
CVE-2026-123892 SDDC Manager Command injection on the appliance 7.2 Important Authenticated, high privileges 9.1.1.0200, 9.0.2.0100, 5.2.5
CVE-2026-123893 SDDC Manager Local privilege escalation to root 6.7 Moderate SDDC Manager admin 9.1.1.0200, 9.0.2.0100, 5.2.5
CVE-2026-123894 VMware Tools for Windows SAML token signature bypass inside the guest 6.7 Moderate Local privileged process; Guest Alias mapping configured 13.1.5.0; 12.5.5 (12.4.10 for 32-bit Windows)

The three SDDC Manager flaws were reported by Arnoldas Radisauskas of NATO NCSC, and the VMware Tools flaw by Noam Pomerantz. None of the four is known to be exploited, and all require some existing access. That said, they should not be dismissed in light of this campaign. An attacker who has already forged administrator tokens through Golden SAML has exactly the authenticated access the SDDC Manager flaws need, and SDDC Manager orchestrates an entire VMware Cloud Foundation deployment.

For CVE-2026-123894, Broadcom notes that disabling guest operations does not remove existing guest aliases or protect against the flaw, and that stopping or uninstalling VMware Tools is not a workaround. Not using guest alias mapping reduces exposure, but configurations change; update Tools anyway.

Not affected: ESX, VCF Operations, VCF Automation, NSX, VMware Workstation, and VMware Fusion. Windows VMs that move from Workstation or Fusion into VCF or vSphere Foundation should run a fixed Tools version.


Fixed versions by deployment

Deployment Fix
VCF / vSphere Foundation 9.1.x vCenter and SDDC Manager 9.1.1.0200
VCF / vSphere Foundation 9.0.x vCenter 9.0.2.0200; SDDC Manager 9.0.2.0100
Standalone vCenter 8.0 8.0 U3m
VCF 5.x vCenter 8.0 U3m and SDDC Manager 5.2.5 via asynchronous patching (KB 88287)
Telco Cloud Platform 3.0, 4.x, 5.0.x, 5.1.x, 5.2; Telco Cloud Infrastructure 3.0 vCenter 8.0 U3m (KB 463116)
vCenter 7.0 No public patch; contact Broadcom if you have an extended support contract
vSphere 6.5 and 6.7 Presume affected; Broadcom no longer evaluates these releases
Third-party engineered systems (e.g., Dell VxRail, HPE SimpliVity) Follow the vendor's guidance

Updates are cumulative and include the earlier VMSA-2026-0008 fixes, so no prerequisite patches are needed.


Two patching pitfalls to plan around

The "Back-in-Time" upgrade block. Installing vCenter 8.0 U3m or 9.0.2.0200 blocks a later upgrade to VCF 9.1.1, because the patched builds are newer than what 9.1.1 expects to upgrade from. Broadcom gives two options: upgrade to 9.1.1 first and then apply the 9.1.1.0200 security update, or patch now and wait for VCF 9.1.2 for your next upgrade. Given confirmed exploitation, most organizations should not delay the security fix to preserve an upgrade path; patch now and plan around 9.1.2 unless a 9.1.1 upgrade was already imminent.

No Quick Patch, and a short management outage. These updates cannot be installed through vCenter Quick Patch. Running VMs and containers keep working during the update, but the vSphere Client and other management interfaces drop briefly, and some encryption operations that use a Standard Key Provider, such as encrypting a new VM or rotating keys, are unavailable until vCenter returns. Schedule accordingly, but do not let this push the change into next month.


What you should do

1. Patch vCenter now

Apply the fixed build for your deployment from the table above. Treat it the way Broadcom does, as an emergency change. If you are unsure whether a given vCenter is affected, Broadcom's guidance is to presume it is.

If you run vCenter 7.0 without an extended support contract, you have no fix. Prioritize the migration to a supported release and, in the meantime, apply the network restrictions in step 2 as tightly as possible.

2. Restrict who can reach vCenter

Broadcom offers no workaround, but network controls reduce exposure while you patch and remain good practice afterward:

  • Allow access to vCenter only from dedicated administrative networks or privileged access workstations. Pay particular attention to TCP port 2012, which this exploit uses, as well as 5480 (appliance management), 443, and 389/636.
  • Do not rely on vCenter's built-in firewall. Mandiant points out that anyone with access to the appliance management interface can disable it, that it does not enforce outbound rules, and that it lacks remote logging for rejected connections. Mandiant's VCSA Hardening & Logging Tool applies default-deny inbound and outbound rules at the kernel level, which the management interface cannot switch off, and forwards logs off the appliance.
  • Block outbound internet access from vCenter and ESXi except where explicitly required. In this intrusion, egress controls would have hampered both data theft and the Slack-based backdoor.

3. Patch the rest of VMSA-2026-0009

Update SDDC Manager in VCF environments and roll out VMware Tools 13.1.5.0 or 12.5.5 to Windows VMs, prioritizing any with Guest Alias mapping configured.

4. Assume compromise if vCenter was reachable from a weak point

If any system that can reach vCenter's management ports was itself exposed, particularly the BeyondTrust Remote Support appliances affected by CVE-2026-102764, other remote access or edge appliances, or Linux appliances without EDR, conduct a compromise assessment rather than just patching. Look for:

  • New or unexpected SSO and local administrator accounts in vsphere.local, including accounts matching sps-*@vsphere.local
  • SSH being enabled and then disabled on the vCenter appliance, visible as PUT /rest/appliance/access/ssh calls to the appliance management API
  • Unusual connections to TCP port 2012 on vCenter, and internal hosts running nmap SYN scans against VMware ports
  • Files in /tmp on vCenter or Linux appliances such as 123, 123.rar, rar, sss, dbr, 123.key, gdb_file, or *_host_key files
  • SUID set on /bin/env, and a vmtoolscs service or /usr/bin/vmtoolscs binary on Linux appliances
  • Listeners on TCP 33992 or 53 on appliances that should not run DNS, and the SSH banner SSH-2.0-pulsesecure_23345
  • JSP web shells named ActiveSer.jsp or u.jsp on Linux appliances
  • On ESXi: unexpected keys in root's authorized_keys, vpxuser logins to the ESXi Host Client, hidden .a directories on VMFS volumes, and o.tar.gz archives
  • Slack API traffic from Linux appliances, and connections to the IP addresses GTIG published, which it describes as a suspected obfuscation network: 103.147.251.5, 103.190.38.3, 118.174.128.34, 118.174.128.36, 118.174.128.38, 176.9.89.66, 185.71.15.109, 220.121.128.41, 222.108.77.44, 61.216.56.127, and 81.45.89.43

GTIG's report includes YARA rules for all six malware families; use them to scan appliance file systems.

Because the attackers deleted SAWSNAKE after use and could have cleared local logs, the absence of evidence on the appliance itself is not proof of safety. Logs forwarded to a SIEM before September are your most reliable record.

5. If you find evidence, rotate identity, not just software

Patching does not invalidate anything the attackers already took. If compromise is confirmed or cannot be ruled out:

  • Replace the vCenter SSO signing certificates (the STS certificate) so that forged SAML tokens stop working.
  • Reset credentials for administrator@vsphere.local, all vCenter administrators, ESXi root, and service accounts, and remove any unauthorized SSH keys.
  • Treat Active Directory as compromised if any domain controller ran as a VM on affected hosts. Theft of NTDS.dit means every password hash in the domain, including the krbtgt account, is in the attackers' hands. That calls for a planned AD recovery, including resetting krbtgt twice.
  • Rebuild compromised appliances from known-good images rather than trying to clean them.

6. Close the visibility gap

This campaign deliberately moved through systems that security teams do not watch: a remote support appliance, a Linux appliance without EDR, vCenter, and ESXi. Forward vCenter, ESXi, and appliance logs to a SIEM that the attacker cannot reach, alert on new vsphere.local administrators and appliance SSH changes, and inventory every appliance that can talk to your virtualization management plane. Mandiant's vSphere and BRICKSTORM Malware: A Defender's Guide is a good starting point.


Summary

What VMSA-2026-0009: five VMware flaws, headlined by CVE-2026-123890 (CVSS 9.8)
Impact Unauthenticated administrator access to vCenter, leading to MFA bypass through forged SAML tokens and control of all managed VMs
Exploitation Zero-day use by China-nexus ARMORY CASTLE since early September 2026; Mandiant reports multiple incidents
Attack chain BeyondTrust zero-day (CVE-2026-102764), then Linux appliances without EDR, then vCenter, then ESXi and Active Directory data
Fix vCenter 9.1.1.0200, 9.0.2.0200, or 8.0 U3m; VCF 5.x via 5.2.5; SDDC Manager and VMware Tools updates for the other four CVEs
Workaround None; restrict access to vCenter, especially TCP 2012, while patching
Watch out for 8.0 U3m and 9.0.2.0200 block upgrades to VCF 9.1.1; vCenter 7.0 has no public patch
If compromised Replace SSO signing certificates, reset privileged credentials, and treat Active Directory as compromised if domain controllers ran on affected hosts

The uncomfortable truth in this disclosure is that organizations doing everything right, patching July's vCenter flaws promptly, still had no defense against this attack until November 19. The patch closes the door; it does not tell you whether someone already walked through it. Patch this week, and if vCenter was reachable from any system you cannot fully vouch for, look before you assume.

If you need help assessing whether your vCenter or ESXi environment shows signs of this activity, hardening access to your virtualization management plane, or rotating identity infrastructure after a suspected compromise, get in touch.